Strain-gage methods for measuring the opening-mode stress-intensity factor,K I |
| |
Authors: | J. W. Dally R. J. Sanford |
| |
Affiliation: | (1) Department of Mechanical Engineering, University of Maryland, 20742 College Park, MD |
| |
Abstract: | Measurements of strain near a crak tip with electrical-resistance strain gages do not usually provide a reliable measure ofK I because of local yielding, three-dimensional effects and limited regions for strain-gage placement. This paper develops expressions for the strains in a valid region removed from the crack tip, and indicates procedures for locating and orienting the gages to accurately determineK I from one or more strain-gage readings. |
| |
Keywords: | |