首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Simultaneous analysis of 23 priority volatile compounds in water by solid-phase microextraction–gas chromatography–mass spectrometry and estimation of the method's uncertainty
Authors:Ana Dias Guimarães  José JoÃo Carvalho  Carlos GonÇalves
Institution:1. IAREN—Water Institute of the Northern Region , Rua Dr. Eduardo Torres, 229/4450-113 Matosinhos, Portugal;2. IAREN—Water Institute of the Northern Region , Rua Dr. Eduardo Torres, 229/4450-113 Matosinhos, Portugal;3. FFUP—Faculty of Pharmacy, Laboratory of Hydrology , University of Porto , Rua Aníbal Cunha, 164/4050-047 Porto, Portugal
Abstract:Most water contaminations with volatile organic compounds (VOCs) are traceable to leaking underground fuel reservoirs, solvent storage vessels, agricultural practices, industrial residues, and deficient wastewater treatment and disposal. In order to perform effective monitoring of such organic micropollutants in a straightforward manner, a multiresidue method for the determination of 23 VOCs (trihalomethanes (THMs), BTEX and chlorinated solvents) in water has been developed using solid-phase microextraction (SPME) and capillary gas chromatography–mass spectrometry (GC–MS). This group includes also methyl-tert-butyl ether, epichlorhydrine, and vinyl chloride which present additional analytical difficulties. Three different fibres were assayed: 7-µm polydimethylsiloxane (PDMS), 100-µm PDMS, and 75-µm Carboxen-PDMS, and the extraction conditions were optimized. The best results for the majority of the analytes and mainly for those with the lowest signals were obtained using the Carboxen-PDMS fibre after 15 min of extraction in the headspace mode at a room temperature of 20 ± 2°C. The analytical sensitivity, linearity, precision, accuracy, and uncertainties have been studied for method validation in agreement with the international standard ISO/IEC 17025:2005. The limits of detection achieved with the proposed method (0.06–0.17 µg L?1) are adequate to determine the VOCs at the restrictive levels established by the European legislation. This was a decisive achievement to enable the analysis of all VOCs listed under the drinking-water directive in a single assay. The method exhibits performance capabilities suitable for routine analysis of VOCs in drinking-water by quality-control laboratories as enforced by EU Directives. The method is currently being used for this purpose, and participation in proficiency tests was assessed, with encouraging results.
Keywords:SPME  Water  VOCs  Epichlorydrine  Vinyl chloride  MTBE  GC-MS  Uncertainty
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号