首页 | 本学科首页   官方微博 | 高级检索  
     


Determination of trace amounts of morphine in human plasma by anodic adsorptive stripping differential pulse voltammetry
Authors:Ali Niazi  Ateesa Yazdanipour
Affiliation:Department of Chemistry, Faculty of Sciences, Azad University of Arak, Arak, Iran
Abstract:New adsorptive anodic differential pulse stripping voltammetry method for the direct determination of morphine at trace levels in human plasma of addicts is proposed.The procedure involves an adsorptive accumulation of morphine on a HMDE,followed by oxidation of adsorbed morphine by voltammetry scan using differential pulse modulation.The optimum conditions for the analysis of morphine are pH 10.5,Eacc of - 100 mV (vs.Ag/AgCl),and tacc of 120 s.The peak current is proportional to the concentration of morphine,and a linear calibration graph is obtained at 0.01-3.10 μg mL-1.A relative standard deviation of 1.06% (n=5) was obtained,and the limit of detection was 3 ng mL- 1.The capability of the method for the analysis of real samples was evaluated by the determination of morphine in spiked human plasma and addicts human plasma with satisfactory results.
Keywords:Morphine  Adsorptive differential pulse voltammetry  Human plasma
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《中国化学快报》浏览原始摘要信息
点击此处可从《中国化学快报》下载全文