In situ dsDNA-bevacizumab anticancer monoclonal antibody interaction electrochemical evaluation |
| |
Authors: | Luciana IN Tomé Nuno V Marques Victor C Diculescu Ana Maria Oliveira-Brett |
| |
Institution: | 1. Chemistry Department, Faculty of Sciences and Technology, University of Coimbra, 3004-535, Coimbra, Portugal;2. Serviços Farmacêuticos, Centro Hospitalar e Universitário de Coimbra, EPE, 3000-075 Coimbra, Portugal |
| |
Abstract: | The interaction of the anticancer monoclonal antibody bevacizumab (BEVA) with double-stranded DNA (dsDNA) was studied by voltammetry and gel-electrophoresis in incubated samples and using the dsDNA-electrochemical biosensor. The voltammetric results revealed a decrease and disappearance of the dsDNA oxidation peaks with increasing incubation time, showing that BEVA binds to the dsDNA but no DNA oxidative damage was detected electrochemically. Non denaturing agarose gel-electrophoresis experiments were in agreement with the voltammetric results showing the formation of compact BEVA-dsDNA adduct. The dsDNA-electrochemical biosensor in incubated solutions showed that BEVA also undergoes structural modification upon binding dsDNA, and BEVA electroactive amino acid residues oxidation peaks were detected. |
| |
Keywords: | Bevacizumab Monoclonal antibody Voltammetry Interaction dsDNA-electrochemical biosensor DNA damage Glassy carbon |
本文献已被 ScienceDirect 等数据库收录! |
|