首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Validation of a Stability-Indicating LC Method for Assay of Ezetimibe in Tablets and for Determination of Content Uniformity
Authors:Ashish S Doshi  Pankaj K Kachhadia  Hemendra S Joshi
Institution:(1) Department of Chemistry, Saurashtra University, Rajkot, 360 005, India
Abstract:A simple, precise, and accurate HPLC method has been developed and validated for assay of ezetimibe in tablets and for determination of content uniformity. Reversed-phase liquid chromatographic separation was achieved by use of phosphoric acid (0.1%, v/v)–acetonitrile 50:50 (v/v) as mobile phase. The method was validated for specificity, linearity, precision, accuracy, robustness, and solution stability. The specificity of the method was determined by assessing interference from the placebo and by stress testing of the drug (forced degradation). Response was a linear function of drug concentration in the range 20–80 μg mL−1 (r = 0.9999). Intraday and interday system and method precision were determined. Accuracy was between 100.8 and 102.7%. The method was found to be robust, and was suitable for assay of ezetimibe in a tablet formulation and for determination of content uniformity. An erratum to this article can be found at
Keywords:Column liquid chromatography  Drug formulation  Cholesterol absorption inhibitor  Ezetimibe
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏