首页 | 本学科首页   官方微博 | 高级检索  
     检索      


A fire field model implemented in a parallel computing environment
Authors:C S Ierotheou  E R Galea
Abstract:This paper describes the implementation of a fire field model in the parallel computing environment offered by multiple transputers. The fire model is built into the general purpose SIMPLE-based CFD code HARWELL-FLOW3D. The technique of domain decomposition has been applied tb convert the conventional serial version of FLOW3D into a code capable of efficiently utilizing an arbitrary number of transputers. Fire simulations consisting of up to 24 000 computational cells are performed on parallel systems with up to 15-processors. The run time for this simulation has been reduced from over 4 days on a single processor to just over 8 h on the 15-processor system. An interactive graphics system has also been developed which runs in parallel with the main computations.
Keywords:Parallel computing  Transputer  CFD  Fire simulation