Investigation into the GC separation of enantiomers on a trifluoroacetylated cyclodextrin. I. Effect of analyte structure on stereoselectivity for alcohols
Authors:Lan D Smith  Colin F Simpson
Abstract:More than 30 enantiomeric alcohols have been analyzed, without prior derivatization, by gas chromatography using a fused silica capillary column coated with octakis(3-O-trifluoro-acetyl-2,6-di-O-n-pentyl)-γ-cyclodextrin. Most were analyzed over a range of isothermal temperatures from 35 to 70°C. Enantiomeric separations were observed for most of the analytes, even at temperatures as low as 35°C. The stereoselectivity of the stationary phase was found to depend on the length of the longest carbon chain attached to the stereogenic centre in 2- and 3-hydroxy alkanes, the relative positions of the methyl and hydroxyl substituents in methylsubstituted alcohols, and the effects of multiple bonds in the analyte molecule. Thermodynamic data calculated from the results suggest that the enantiomers of all the analytes are resolved by a similar process. Retention and thermodynamic data are presented and possible mechanisms discussed.
Keywords:Gas chromatography  Resolution of enantiomers  Chiral stationary phase  Derivatized cyclodextrin  Trifluoroacetylated cyclodextrin  Structural effects  Thermodynamic properties