首页 | 本学科首页   官方微博 | 高级检索  
     

铊(I)离子选择电极动力学分析法测定超痕量铁
引用本文:仰蜀薰,仝华翔. 铊(I)离子选择电极动力学分析法测定超痕量铁[J]. 化学学报, 1987, 45(7): 711-714
作者姓名:仰蜀薰  仝华翔
作者单位:郑州大学化学系
摘    要:

关 键 词:  硫酸亚铁    离子选择电极  痕量分析  过氧化氢  动力学分析  铊离子  电位测定  水质水析  

Kinetic determination of ultra trace ferrous ion with thallium (I) ion selective electrode
YANG SHUXUN,TONG HUAXIANG. Kinetic determination of ultra trace ferrous ion with thallium (I) ion selective electrode[J]. Acta Chimica Sinica, 1987, 45(7): 711-714
Authors:YANG SHUXUN  TONG HUAXIANG
Abstract:Fe(II) induces the reaction between Tl3+ and H2O2. The rate of reaction is linearly proportional to the concentration of Fe2+ in the range 2.5 ?10-9-2.5 ?10-8 mol dm-3 (20? and 5 ?10-9-5 ?10-8 mol dm-3 (15?. The standard deviation is less than 0.071 ?10-8. A 1000-fold excess of Zn2+, Cd2+, Mg2+, Ni2+, Pb2+, Ba2+, Ca2+, Li+, Na+, Ag+, NO3-, SO42-, AcO-, HPO42-, 500-fold excess of Al3+, Fe3+, Co2+, Hg2+ and 100-fold excess of Ti4+, Cr3+, Cu2+, Br-, Cl- can be tolerated, but reducing agents such as (NH2)2SO4, NH2OH.HCl interfered. This kinetic method was applied to determine Fe(II) in standard zinc sample and fountain water, with satisfactory results.
Keywords:ZINC  FERROUS SULFATE  IRON  ION SELECTIVE ELECTRODE  TRACE ANALYSIS  HYDROGEN PEROXIDE  KINETIC ANALYSIS  THALLIUM ION  POTENTIOMETRIC DETERMINATION  WATER QUALITY ANALYSIS
点击此处可从《化学学报》浏览原始摘要信息
点击此处可从《化学学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号