首页 | 本学科首页   官方微博 | 高级检索  
     检索      


N-Nitrosodimethylamine Contamination in the Metformin Finished Products
Authors:Adam Zmys&#x;owski  Iza Ksi&#x; ek  Arkadiusz Szterk
Institution:National Medicines Institute, 30/34 Chełmska, 00-725 Warsaw, Poland; (I.K.); (A.S.)
Abstract:A GC–MS/MS method with EI ionization was developed and validated to detect and quantify N-nitrosodimethylamine (NDMA) and seven other nitrosamines in 105 samples of metformin tablets from 13 different manufactures. Good linearity for each compound was demonstrated over the calibration range of 0.5–9.5 ng/mL. The assay for all substances was accurate and precise. NDMA was not detected in the acquired active pharmaceutical ingredient (API); however, NDMA was detected in 64 (85.3%) and 22 (91.7%) of the finished product and prolonged finished product samples, respectively. European Medicines Agency recommends the maximum allowed limit of 0.032 ppm in the metformin products. Hence, 28 finished products and 7 pronged dosage products were found to exceed the acceptable limit of daily intake of NDMA contamination. The implications of our findings for the testing of pharmaceutical products are discussed.
Keywords:NDMA  nitrosamines  GC-MS  metformin
设为首页 | 免责声明 | 关于勤云 | 加入收藏