In situ Molecular Self-assembly and Sensitive Label-free Detection of Streptavidin via a Wavelength Interrogated Surface Plasmon Resonance Sensor
Authors:YU Yong-jiang  ZHOU Ying  LI Qiu-shun  YANG Yan  SHI Jian-guo  LI Ming-yu  YAO Wei-guo  WANG Jun-nan  DONG Wen-fei  QI Zhi-mei
Institution:[1]State Key Laboratory on Integrated Optoelectronics, College of Integrated Optoelectronics,Jilin University, Changchun 130012, P.R.China [2]Key Biosensor Laboratory of Shandong Province, Biology Institute of Shandong Academy of Sciences,Jinan 250014, P.R.China [3]State Key Laboratory of Modern Optical Instrumentation, Zhejiang University, Hangzhou 310027, P.R.China [4]Key Laboratory of Automobile Materials, Ministry of Education, Department of Materials Science and Engineering,Jilin University, Changchun 130025, P.R.China [5]The Second Hospital of Jilin University, Changehun 130041, P. R. China [6]State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, P. R. China
Abstract:The sensing sensitivity of wavelength interrogated surface plasmon resonance(WISPR) biosensor is improved by self-assembly of polyelectrolyte multilayer(PEM) film of poly(allylamine hydrochloride)(PAH)/ poly(sodium-p-styrenesulfonate)(PSS) on the Au film coated glass chip via the layer-by-layer(LBL) technique. The home-made WISPR with Krestchmann configuration consists of a tungsten-halogen lamp as a photon source and a charge coupled device(CCD) camera as the detector. The influence of PEM film thickness on the optical properties of WISPR biosensors was investigated theoretically and experimentally. In order to achieve higher sensing sensitivity, the PEM film thickness has to be designed as ca.14 nm at an Au layer thickness of 50 nm and an incidental angle of 11.8°. Furthermore, the PEM coated WISPR biosensor can serve as highly sensitive biosensor, in which the biotin-streptavidin is used as bioconjugate pair. After deposition of the PEM film of (biotin/PAH)(PSS/PAH)3, the mo-dified WISPR biosensor is more sensitive to the low concentration(<0.01 mg/mL) of streptavidin. And the sensing sensitivity can be further increased by one order of magnitude compared with that of the biotin/PAH coated WISPR biosensor. Thus, such low-cost, high-performance and efficient PEM-coated WISPR biosensors have great potentials in a diverse array of fields such as medical diagnostics, drug screening, food safety analysis, environmental monito-ring, and homeland security.
Keywords:Polyelectrolyte multilayer  Sensing sensitivity  Biosensor  Wavelength interrogated surface plasmon resonance
本文献已被 维普 等数据库收录!
点击此处可从《高等学校化学研究》浏览原始摘要信息
点击此处可从《高等学校化学研究》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号