Abstract:The absolute concentration and translational temperature of the 2p10 and 2p7 excited states of argon have been measured in an inductively coupled plasma chamber under a variety of operating conditions using both calibrated diode laser frequency modulation spectroscopy and cavity enhanced absorption spectroscopy. Accurate lineshape analysis of frequency modulation signals has been employed to extract the desired information, and is corroborated by cavity enhanced measurements. Temperatures are found to vary linearly with pressure from ∼400 K at 20 mTorr (2.7 Pa) to ∼510 K at 90 mTorr (12 Pa) in a 200 W discharge while concentrations peak at 3.25×108 cm-3 at 30 mTorr (4 Pa) (also in a 200 W discharge). The uncertainty in the recovered temperature is 7%, dominated by uncertainties in the calibration of the frequency scale. PACS 42.62Fi; 52.70kz