A direct formulation of correlations for wall-proximity corrections of hot-wire measurements
Authors:M Acharya  M P Escudier
Institution:(1) Brown Boveri Research Center, CH-5405 Baden, Switzerland
Abstract:Correlations for corrections to hot-wire data for the effects of wall proximity within the viscous sublayer are usually presented in the form Deltau/u tau = F (y u tau/ugr). The application of such correlations requires a prior knowledge of the wall shear stress; alternatively, the correlation must be used in an iterative fashion. It is shown in the present note that any such correlation may be recast with no loss of generality in the explicit form Deltau/u m = f (y u m/ugr), which is more convenient for use.List of symbols Deltau difference between measured and actual velocities, equiv u mu - u m measured velocity - u tau shear velocity, equiv 
$$\sqrt {\tau _s /\varrho }$$
- u + on-dimensional velocity, equiv u/u tau - y distance from wall - y + non-dimensional distance from wall, equiv y u tau/ugr - rhov fluid density - ugr fluid kinematic viscosity - tau s wall shear stress