Characteristics of millimeter wave detection in a Fabry-Perot resonator using a YBCO-BiO composite superconductor
Authors:K Niki  T Idehara  T Tatsukawa  I Ogawa and Y Yoshisato
Institution:(1) Department of Applied Physics, Faculty of Engineering, Fukui University, 910 Fukui, Japan;(2) Tsukuba Research Center, SANYO Electric Co., Ltd., 305 Tsukuba, Ibaraki, Japan
Abstract:A quasioptical technique with a hemispherical-type Fabry-Perot resonator for measuring characteristics of millimeter wave detection using a YBCO-BiO composite superconductor has been successfully developed. This Fabry-Perot resonator consists of a spherical mirror and a plane mirror mounted on the cold head of the refrigerator, under a controlled temperature of 40 to 300 K. The method offers the advantages of estimating irradiation power, easily controlling the sample temperature, analyzing the mode of the irradiated millimeter waves and easily extending to higher frequencies. The superconducting millimeter wave detector has been measured with this technique, with measured sensitivities of 46.5 V/W (70 K) to 160 V/W (35 K) at 50 GHz. These results are close to the theoretical values calculated numerically from the characteristics of the detector. It was confirmed that the millimeter wave detection system using the Fabry-Perot resonator is suitable for estimating the sensitivity of the high-Tc superconducting millimeter wave detector.
Keywords:superconductor  radiation detector  millimeter wave  Fabry-Perot resonator
本文献已被 SpringerLink 等数据库收录!