Measurements of HO2 uptake coefficient on aqueous (NH4)2SO4 aerosol using aerosol flow tube with LIF system |
| |
Authors: | Qi Zou Huan Song Mingjin Tang Keding Lu |
| |
Institution: | College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China; State Key Laboratory of Geochemistry and Guangdong Key Laboratory of Environmental Protection and Resources Utilization, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640, China |
| |
Abstract: | Laboratory studies of HO2 uptake coefficients, γ(HO2), were conducted at room temperature using an aerosol flow tube coupled with a laser induced fluorescence (LIF) system. The measurement was conducted with atmospherically relevant HO2 concentrations (~1×109 molecule/cm3) at 51% RH. The measured γ(HO2) onto aqueous (NH4)2SO4 aerosol was 0.001 ±0.0007, which was consistent with the relatively low first-order loss rate of HO2 onto aqueous (NH4)2SO4 aerosol. The γ(HO2) was elevated with increase of Cu(II) concentrations in aqueous (NH4)2SO4 aerosol. The threshold of Cu(II) concentration was 10-3 mol/L for the dramatic increase of γ(HO2). It was found that γ(HO2) reached 0.1 when Cu(II) concentration in aerosol was larger than 10-3 mol/L, suggesting that γ(HO2) is very sensitive to concentration of transition metal ions in aerosol. |
| |
Keywords: | Heterogeneous reaction HO2 uptake coefficient Aerosol flow tube Laser induced fluorescence Transition metal ion |
|
| 点击此处可从《中国化学快报》浏览原始摘要信息 |