首页 | 本学科首页   官方微博 | 高级检索  
     检索      

磁化溶液样品对ICP发射光谱的增敏效应
引用本文:陈金忠,周永利,郭庆林,怀素芳,魏艳红.磁化溶液样品对ICP发射光谱的增敏效应[J].光谱学与光谱分析,2008,28(8):1923-1927.
作者姓名:陈金忠  周永利  郭庆林  怀素芳  魏艳红
作者单位:河北大学物理科学与技术学院,河北,保定,071002;河北大学物理科学与技术学院,河北,保定,071002;河北大学物理科学与技术学院,河北,保定,071002;河北大学物理科学与技术学院,河北,保定,071002;河北大学物理科学与技术学院,河北,保定,071002
摘    要:利用磁感应强度为0.24T的磁场处理含乙醇的水溶液,研究了样品溶液的物理性质和雾化特性以及样品溶液中元素的谱线强度随磁化时间的变化情况,并且讨论了磁化机理。实验结果表明,随着磁处理时间的延长,分析样品的有效利用率提高了;当样品中加入乙醇时,元素的谱线强度较早地出现了峰值。在磁化时间为2 h的条件下,不含乙醇的样品溶液中,元素Zn, Pb, Cd, Fe, Si, Cu, Cr和Sr的谱线强度比溶液未磁化时分别提高了22.9%, 38.8%, 25.6%, 48.3%, 52.4%, 6.0%, 22.3%和22.7%;含6%乙醇的样品溶液中,元素Zn, Pb, Cd, Fe, Si, Cu, Cr和Sr的谱线强度比溶液未磁化时分别增加了22.4%, 42.6%, 39.4%, 43.9%, 72.4%, 9.7%, 16.1%和17.1%。样品溶液磁化后进行分析, 有利于降低光谱分析检出限。

关 键 词:磁化溶液  乙醇  物理性质  雾化特性  谱线强度
收稿时间:2007-05-08

Enhancing Effect of Magnetizing Solution Sample on Inductively Coupled Plasma Atomic Emission Spectrum
CHEN Jin-zhong,ZHOU Yong-li,GUO Qing-lin,HUAI Su-fang,WEI Yan-hong.Enhancing Effect of Magnetizing Solution Sample on Inductively Coupled Plasma Atomic Emission Spectrum[J].Spectroscopy and Spectral Analysis,2008,28(8):1923-1927.
Authors:CHEN Jin-zhong  ZHOU Yong-li  GUO Qing-lin  HUAI Su-fang  WEI Yan-hong
Institution:College of Physics Science and Technology, Hebei University, Baoding 071002, China
Abstract:In the present paper,the physics property and nebulization character of the sample solution as well as elemental spectrum intensity were investigated with the prolonging of magnetization time after the water solution with the ethanol was magnetized under magnetic field of 0.24T.The magnetization mechanism was discussed.The experiment result shows that the efficient age-rate of the analyzed sample is increased.The peak values of the spectrum intensity appear when the ethanol is added into the sample.Under the magnetization time of 2 hours,the spectrum intensities of Zn,Pb,Cd,Fe,Si,Cu,Cr and Sr in the sample solution without the ethanol were increased by 22.9%,38.8%,25.6%,48.3%,52.4%,6.0%,22.3% and 22.7% than that with the non-magnetic water,respectively;The signal intensities of the elements in the sample solution with the ethanol of 6% were increased by 22.4%,42.6%,39.4%,72.4%,43.9%,9.7%,16.1% and 17.1% than that with the non-magnetic water,respectively.The detection limit of spectral analysis was reduced when the magnetized sample solution was analyzed.
Keywords:Magnetizing solution  Ethanol  Physical property  Nebulization character  Spectrum intensity
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《光谱学与光谱分析》浏览原始摘要信息
点击此处可从《光谱学与光谱分析》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号