LC–APCI–MS Quantitative Analysis of Curcumin in Rabbit Plasma
Authors:Xuezhi Yang  Jianshe Ma  Yun Ye  Yuan Zhang  Guanyang Lin  Yuancai Zheng  Xu Li  Xianqin Wang
Institution:1. The First Affiliated Hospital of Wenzhou Medical College, Wenzhou, 325000, China
2. School of Basic Medical Sciences of Wenzhou Medical College, Wenzhou, 325035, China
3. Analytical and Testing Center of Wenzhou Medical College, Wenzhou, 325035, China
Abstract:A simple and specific liquid chromatography–atmospheric pressure chemical ionization–mass spectrometry (LC–APCI–MS) method was developed and validated for quantitative analysis of curcumin in rabbit plasma. Chromatographic separation was carried out on Zorbax SB-C18 column, acetonitrile-methanol–water used as mobile phase with gradient elution. APCI source was applied and operated in negative ion mode, and selective ion monitoring mode used to quantify curcumin. The method showed excellent intra-assay and inter-assay precision (relative standard deviations and bias <15%) for quality control (QC) samples. This method was successfully applied to a pharmacokinetic study of curcumin after intravenous administration to rabbits.