首页 | 本学科首页   官方微博 | 高级检索  
     检索      

火焰原子吸收光谱法同时测定尿中钙镁
引用本文:白钰,欧阳健明,白燕,陈美鸾.火焰原子吸收光谱法同时测定尿中钙镁[J].光谱学与光谱分析,2004,24(8):1016-1019.
作者姓名:白钰  欧阳健明  白燕  陈美鸾
作者单位:暨南大学生物矿化与结石病防治研究所,广东,广州,510632;暨南大学生物矿化与结石病防治研究所,广东,广州,510632;暨南大学生物矿化与结石病防治研究所,广东,广州,510632;暨南大学生物矿化与结石病防治研究所,广东,广州,510632
基金项目:广州市重点科技项目(SZ 61 3),广东省重点攻关项目(C31 4 0 1 ),广东省自然科学基金(0 1 32 0 2 ),国家自然科学基金重点项目(2 0 0 31 0 1 0 ),广东省“千百十工程”优秀人才基金 (Q0 2 0 60 )资助项目
摘    要:采用火焰原子吸收光谱法 ,同时测定了尿中钙和镁的含量 ,确定了钙、镁的最佳测试条件。测定钙时 ,波长 4 2 2 8nm ,空心阴极灯的工作电流 3mA ;测定镁时 ,波长 2 85 2nm ,工作电流 4mA ;燃烧器高度均为 8mm ,空气 乙炔流量比均为 6∶1,狭缝宽度 0 2mm。为了消除磷酸盐、硫酸盐和硅酸盐对测定钙浓度的干扰 ,可以加入释放剂 ,其中氯化镧为最佳释放剂。当稀释比例达到 1∶10 0时 ,可以消除尿基质的干扰。通过对 15例尿样的检测 ,尿样的钙和镁值与文献中所提供的浓度值区间一致 ,方法的回收率为 98%~10 4 % ;对于同一样品测试的标准偏差为 1 8% ,P <0 0 5。

关 键 词:尿液分析      原子吸收光谱
文章编号:1000-0593(2004)08-1016-04
修稿时间:2003年3月16日

Simultaneous Determination of Calcium and Magnesium in Urines by Flame Atomic Absorption Spectrometry
Yu Bai,Jian-Ming Ouyang,Yan Bai,Mei-Luan Chen.Simultaneous Determination of Calcium and Magnesium in Urines by Flame Atomic Absorption Spectrometry[J].Spectroscopy and Spectral Analysis,2004,24(8):1016-1019.
Authors:Yu Bai  Jian-Ming Ouyang  Yan Bai  Mei-Luan Chen
Institution:Institute of Biomineralization and Lithiasis Research, Ji'nan University, Guangzhou 510632, China.
Abstract:The contents of calcium and magnesium in urines were simultaneously determined by flame atomic absorption spectrometry. The optimized working conditions were ascertained. For the determination of calcium, the used wavelength was 422.8 nm, and the current of HCL(Hollow Cathode Lamp) was 3 mA; for the determination of magnesium, the used wavelength was 285.2 nm, and the current of HCL (Hollow Cathode Lamp) was 4 mA. The height of burner and the air-acetylene ratio were 8 mm and 6:1, respectively, for the determination of both calcium and magnesium. In order to remove the disturbance of phosphate, sulphate and silicate on the determination of calcium, a releasing reagent can be used. Lanthanum chloride (LaCl3) was tested as a better releasing reagent than strontium chloride (SrCl2). The disturbance of urinary substrate could be avoided after the urines were diluted to 1:100 with distilled water. The concentrations of Ca and Mg in 15 urines were determined under the optimized conditions. The obtained results were consistent with the archived data. The recovery was 96%-104%, the relative standard deviation for a sample was 1.8% with P < 0.05.
Keywords:Urine analysis  Calcium  Magnesium  Flame atomic absorption spectrometry
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号