Gel-permeation chromatography: Examination of universal calibration procedures for polydimethylsiloxane in a poor solvent
Authors:J V Dawkins  J W Maddock  D Coupe
Abstract:Various procedures for universal calibration in gel-permeation chromatography with polystyrene gels are examined for polystyrene and polydimethylsiloxane fractions. For o-dichlorobenzene at 138°C, experimental intrinsic viscosity–molecular weight data show that the Mark-Houwink exponents are 0.70 and 0.57 for polystyrene and polydimethylsiloxane, respectively. In principle, this difference permits a distinction between the various polymer size parameters proposed for universal calibration. An interpretation of the experimental polydimethylsiloxane calibration for o-dichlorobenzene at 138°C requires a consideration of errors in average molecular weights and errors arising from the use of average molecular weight instead of peak molecular weight. When calibration procedures utilizing hydrodynamic volume and unperturbed dimensions are examined, the difference between them is comparable with experimental error. If the Flory-Fox viscosity expression is employed, the perturbed end-to-end distance (or radius of gyration) and the hydrodynamic volume give equivalent universal calibrations. The experimental data are sufficiently accurate to show that the perturbed dimension determined with the Ptitsyn-Eizner relation does not give an adequate universal calibration.