引用本文:陈扉然,颜平秋,周牡艳,黄国泉,吴 坚,金 晶. 电感耦合等离子体质谱法(ICP-MS)测定米托坦中的汞[J]. 中国无机分析化学, 2013, 3(3): 57-60
作者姓名:陈扉然  颜平秋  周牡艳  黄国泉  吴 坚  金 晶
作者单位:绍兴市质量技术监督检测院,浙江 绍兴 312071;浙江苏泊尔制药有限公司,浙江 绍兴 312071;绍兴市质量技术监督检测院,浙江 绍兴 312071;浙江苏泊尔制药有限公司,浙江 绍兴 312071;绍兴市质量技术监督检测院,浙江 绍兴 312071;绍兴市质量技术监督检测院,浙江 绍兴 312071
摘    要:介绍了电感耦合等离子体质谱法(ICP-MS)测定米托坦中的汞,重点从消解方式、酸体系和微波消解程序等方面对样品前处理方法进行了优化。在优化的实验条件下,方法的检出限为0.005mg/kg,6次平行测定结果的相对标准偏差为7.7%,加标回收率为82.3%~85.7%。方法灵敏度高、稳定性好,而且准确度高。

关 键 词:电感耦合等离子体质谱(ICP-MS)  米托坦    微波消解
收稿时间:2013-03-14
修稿时间:2013-04-25

Determination of Mercury in Mitotane by Inductively Couple Plasma-Mass Spectrometry(ICP-MS)
CHEN Feiran,YAN Pingqiu,ZHOU Muyan,HUANG Guoquan,WU Jian and JIN Jing. Determination of Mercury in Mitotane by Inductively Couple Plasma-Mass Spectrometry(ICP-MS)[J]. Chinese Journal of Inorganic Analytical Chemistry, 2013, 3(3): 57-60
Authors:CHEN Feiran  YAN Pingqiu  ZHOU Muyan  HUANG Guoquan  WU Jian  JIN Jing
Affiliation:Shaoxing Municipal Institute of Quality and Technical Supervision Testing, Shaoxing, Zhejiang 312071, China;Zhejiang Supor Pharmaceuticals Co. Ltd., Shaoxing, Zhejiang 312071, China;Shaoxing Municipal Institute of Quality and Technical Supervision Testing, Shaoxing, Zhejiang 312071, China;Zhejiang Supor Pharmaceuticals Co. Ltd., Shaoxing, Zhejiang 312071, China;Shaoxing Municipal Institute of Quality and Technical Supervision Testing, Shaoxing, Zhejiang 312071, China;Shaoxing Municipal Institute of Quality and Technical Supervision Testing, Shaoxing, Zhejiang 312071, China
Abstract:This article introduced a sensitive, reliable and accurate approach for the determination of mercury in Mitotane using inductively coupled plasma-mass spectrometry(ICP-MS). The focus of this work is to optimize sample pretreatment procedure by investigating digestion methods, choice of acid system, and the microwave digestion programs. Under the optimized conditions, the detection limit was 0. 005 mg/kg. The relative standard deviation was 7.7 G for six parallel sample analyses. The spike recovery was in the rang of 82.3%-85.7%. The method has high sensitivity, good stability and high accuracy.
Keywords:inductively couple plasma mass spectrometry(ICP-MS)   mitotane   mercury   microwave digestion