首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Development of a liquid chromatography/tandem-mass spectrometry assay for the simultaneous determination of teneligliptin and its active metabolite teneligliptin sulfoxide in human plasma
Authors:Jin-Woo Park  Kyoung-Ah Kim  Ji-Young Park
Institution:Department of Clinical Pharmacology and Toxicology, Anam Hospital, Korea University College of Medicine, Seoul, Korea
Abstract:Teneligliptin is a recently developed dipeptidyl peptidase-4 (DPP-4) inhibitor for the treatment of type 2 diabetes mellitus. To study simultaneous pharmacokinetics of teneligliptin and its major active metabolite, teneligliptin sulfoxide in human plasma, we developed and validated a LC-MS/MS method. The analytes were detected in the positive mode using multiple reaction monitoring (teneligliptin: m/z 427.2→243.1; teneligliptin-d8: m/z 435.2→251.3; teneligliptin sulfoxide: m/z 443.2→68.2). The method demonstrated accuracy, precision, and linearity over the concentration range of 5 to 1000 ng/mL for teneligliptin and 2.5 to 500 ng/mL for teneligliptin sulfoxide. The developed method is the first fully validated method capable of simultaneous determination of teneligliptin and its active metabolite, teneligliptin sulfoxide in plasma. The suitability of the method was successfully demonstrated in terms of quantification of teneligliptin and teneligliptin sulfoxide pharmacokinetics in plasma samples collected from healthy volunteers. The measurement of plasma metabolite/parent ratio of teneligliptin was feasible by this method.
Keywords:teneligliptin  teneligliptin sulfoxide  LC-MS/MS