首页 | 本学科首页   官方微博 | 高级检索  
     


Low-cost and versatile analytical tool with purpose-made capillary electrophoresis coupled to contactless conductivity detection: Application to antibiotics quality control in Vietnam
Authors:Thai Binh Le  Peter C. Hauser  Thi Ngoc Mai Pham  Thi Lan Phuong Kieu  Thi Phuong Quynh Le  Quoc Anh Hoang  Dinh Chi Le  Thi Anh Huong Nguyen  Thanh Duc Mai
Affiliation:1. Department of Analytical Chemistry, Faculty of Chemistry, University of Science, Vietnam National University, Hanoi, Hanoi, Vietnam;2. Department of Chemistry, University of Basel, Basel, Switzerland;3. Institute of Natural Product Chemistry, Vietnam Academy of Science and Technology, Hanoi, Vietnam;4. Department of Analytical Chemistry and Toxicology, Hanoi University of Pharmacy, Hanoi, Vietnam;5. CNRS, Institut Galien Paris-Saclay, Université Paris-Saclay, Châtenay-Malabry, France
Abstract:In this study, the development of our purpose-made capacitively coupled contactless conductivity detection (C4D) for CE is reported. These systems have been employed as a simple, versatile, and cost-effective analytical tool. CE-C4D devices, whose principle is based on the control of the ion movements under an electrical field, can be constructed even with a modest financial budget and limited infrastructure. A featured application was developed for quality control of antimicrobial drugs using CE-C4D, with most recent work on determination of aminoglycoside and glycopeptide antibiotics being communicated. For aminoglycosides, the development of CE-C4D methods was adapted to two categories. The first one includes drugs (liquid or powder form) for intravenous injection, containing either amikacin, streptomycin, kanamycin A, or kanamycin B. The second one covers drugs for eye drops (liquid or ointment form), containing either neomycin, tobramycin, or polymyxin. The CE-C4D method development was also made for determination of some popular glycopeptide antibiotics in Vietnam, including vancomycin and teicoplanin. The best detection limit achieved using the developed CE-C4D methods was 0.5 mg/L. Good agreement between results from CE-C4D and the confirmation method (HPLC- Photometric Diode Array ) was achieved, with their result deviations less than 8% and 13% for aminoglycoside and glycopeptide antibiotics, respectively.
Keywords:Antibiotics  Capacitively coupled contactless conductivity detection (C4D)  CE  Purpose-made instrumentation  Screening analysis
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号