首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Electrical Conductivity Measurement Through the Loaded Q Factor of a Resonant Cavity
Authors:Joaquim J Barroso  Pedro J Castro and Joaquim P Leite Neto
Institution:(1) Associated Plasma Laboratory, National Institute for Space Research, P.O. Box 515, S.J. Campos, 12245-970 SP, Brazil
Abstract:We present a method for measuring the electrical conductivity of metallic materials that relies on the ratio of two loaded Q factors, QR/QX, with QR corresponding to a TE011-mode reference cavity made of aluminum, and QX the Q that results upon replacing the aluminum plate with the one fabricated from the material to be examined. Electrical conductivity is mathematically inferred from the ratio QR/QX where the loaded Q factors are measured by using the transmission-type method. Within a 3.0 percent accuracy, conductivities determined at 8.7 GHz for electrolytic copper (5.6 times 107 S/m) and brass (1.6 times 107 S/m) show to be in good agreement with those reported in the literature.
Keywords:electrical conductivity measurement  resonant cavity  quality Q factor
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号