首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Selectivity for glucose,glucose-6-phosphate,and pyruvate in ternary mixtures from the multivariate analysis of near-infrared spectra
Authors:Lingzhi Liu  Mark A Arnold
Institution:(1) Department of Chemistry and Optical Science Technology Center, University of Iowa, Iowa City, IA 52242, USA;(2) Present address: College of Pharmacy/CPST, University of Kentucky, 725, Rose Street, Lexington, KY 40536, USA
Abstract:Near-infrared spectroscopy offers the potential for direct in situ analysis in complex biological systems. Chemical selectivity is a critical issue for such measurements given the extent of spectral overlap of overtone and combination spectra. In this work, the chemical basis of selectivity is investigated for a set of multivariate calibration models designed to quantify glucose, glucose-6-phosphate, and pyruvate independently in ternary mixtures. Near-infrared spectra are collected over the combination region (4,000–5,000 cm−1) for a set of 60 standard solutions maintained at 37 °C. These standard solutions are composed of randomized concentrations (0.5–30 mM) of glucose, glucose-6-phosphate, and pyruvate. Individual calibration models are constructed for each solute by using the partial least-squares (PLS) algorithm with optimized spectral range and number of latent variables. The resulting standard errors are 0.90, 0.72, and 0.32 mM for glucose, glucose-6-phosphate, and pyruvate, respectively. A pure component selectivity analysis (PCSA) demonstrates selectivity for each solute in these ternary samples. The concentration of each solute is also predicted for each sample by using a set of net analyte signal (NAS) calibration models. A comparison of the PLS and NAS calibration vectors demonstrates the chemical basis of selectivity for these multivariate methods. Selectivity of each PLS and NAS calibration model originates from the unique spectral features associated with the targeted analyte. Overall, selectivity is demonstrated for each solute with an order of sensitivity of pyruvate > glucose-6-phosphate > glucose. MediaObjects/216_2008_2475_Figa_HTML.gif Figure Combination near-infrared spectroscopy allows selective analytical measurements for glucose, glucose-6-phosphate, and pyruvate in ternary mixtures owing to the uniqueness of the individual absorption spectra for each solute
Keywords:Near-infrared spectroscopy  Glucose  Glucose-6-phosphate  Pyruvate  Partial least-squares  Net analyte signal  Multivariate analysis selectivity
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号