首页 | 本学科首页   官方微博 | 高级检索  
     

利用质子能损检测气体靶区有效靶原子密度的实验研究
引用本文:陈燕红,程锐,张敏,周贤明,赵永涛,王瑜玉,雷瑜,麻鹏鹏,王昭,任洁茹,马新文,肖国青. 利用质子能损检测气体靶区有效靶原子密度的实验研究[J]. 物理学报, 2018, 67(4): 44101-044101. DOI: 10.7498/aps.67.20172028
作者姓名:陈燕红  程锐  张敏  周贤明  赵永涛  王瑜玉  雷瑜  麻鹏鹏  王昭  任洁茹  马新文  肖国青
作者单位:1. 中国科学院近代物理研究所, 兰州 730000;2. 西安交通大学, 西安 710049;3. 中国科学院大学, 北京 100049;4. 西北师范大学, 兰州 730070
基金项目:国家重点基础研究发展计划(批准号:2017YFA0402303)和国家自然科学基金(批准号:U1532263,11505248,11375034,11775042,11775278,11605147)资助的课题.
摘    要:准确测量气态靶区的有效靶原子密度能够提升离子与气体和离子与等离子体靶相互作用实验结果的精度和对物理过程的认识.实验中利用离子加速器引出的100 ke V质子束穿过一定长度的氢气靶,对质子的剩余能量进行了精确测量,获得了在气体靶内的质子能损数据,结合已有的能损研究结果,重新标定了气体靶区内的有效靶原子密度.分别比较了能损、电离型真空计IonIVac ITR 90和薄膜电容型真空计Varian CDG-500的实验测量结果,对比了修正后的电离型真空计有效气压曲线,结果发现质子束能损的测量方式具有原位、高准确性、在线监测等突出优势,为诊断气态靶有效原子密度提供了新的方法.

关 键 词:质子束  气体靶  能量损失  有效靶原子密度
收稿时间:2017-09-13

Experimental investigation on diagnosing effective atomic density in gas-type target by using proton energy loss
Chen Yan-Hong,Cheng Rui,Zhang Min,Zhou Xian-Ming,Zhao Yong-Tao,Wang Yu-Yu,Lei Yu,Ma Peng-Peng,Wang Zhao,Ren Jie-Ru,Ma Xin-Wen,Xiao Guo-Qing. Experimental investigation on diagnosing effective atomic density in gas-type target by using proton energy loss[J]. Acta Physica Sinica, 2018, 67(4): 44101-044101. DOI: 10.7498/aps.67.20172028
Authors:Chen Yan-Hong  Cheng Rui  Zhang Min  Zhou Xian-Ming  Zhao Yong-Tao  Wang Yu-Yu  Lei Yu  Ma Peng-Peng  Wang Zhao  Ren Jie-Ru  Ma Xin-Wen  Xiao Guo-Qing
Affiliation:1. Institute of Modern Physics, Chinese Academic of Science, Lanzhou 730000, China;2. Xi'an Jioatong University, Xi'an 710049, China;3. University of Chinese Academic of Scienc, Beijing 100049, China;4. Northwest Normal University, Lanzhou 730070, China
Abstract:The investigations of interaction processes between ion beams and gas and between ion beams and plasma play important roles in atomic physics, astrophysics, high energy density physics, and inertial confinement fusion.The atomic density of target is one of the key experimental parameters which may determine the interaction mechanism and experimental results.How to precisely diagnose the atomic density of target in different matter states, like gas phase and plasma phase, is challenging work on the experiments in laboratory.Conventionally the vacuum gauges are used to measure the pressure inside the gas target, but the accuracy is limited for a complex target system and they can hardly work in a strong radiation surrounding, especially in plasma where the high temperature can physically damage the gauges.Therefore we propose a new method to measure the atomic densities for both gas target and plasma target based on the heavy ion beam accelerator facility at the Institute of Modern Physics, Chinese Academy of Sciences.In our experiment the protons are extracted from an electron cyclotron resonance ion source (ECRIS) and accelerated to 100 keV then transmitted to the target.A two-stage differential pumping system is constructed to keep 10-7 mbar order of magnitude in beam line when the gas is filled into the target area where the pressure could increase to higher than 1 mbar.A 45° dipole magnet is used to bend the protons which have passed through the gas.The energy is determined by the different positions of protons at the position-sensitive detector which is placed at the end of magnet.Consequently the energy losses of protons at different pressures are obtained.There have been proposed many theories for calculating the energy loss of protons in gas, and we chose the very popular code named SRIM to simulate the experimental case. Finally the effective linear atomic density of target along the ion beam trajectory in the target area is obtained.For comparison, the conventional vacuum gauges (one is the hot cathode gauge-IonIVac ITR 90 and the other is capacitance diaphragm gauge-Varian CDG-500) are simultaneously used in the experiment.The results show that the recalibrated effective pressure obtained by the energy loss is close to the pressure measured by Varian CDG-500 but much lower than the pressure from IonIVac ITR 90.Only after the detection efficiency correction, could the corrected results of IonIVac ITR 90 be coincident with the effective pressure obtained according to energy loss.Moreover we find that the effective atomic density determined by the protons energy loss shows that these advantages over the conventional gauges are not only the high accuracy and reliability but also the in-situ measurement, high temporal resolution and the ability to work in the complex radiation and hot plasma environment.These properties may play a great role in the experimental researches and relevant topics.
Keywords:proton beam  gas target  energy loss  effective atomic density number
本文献已被 CNKI 等数据库收录!
点击此处可从《物理学报》浏览原始摘要信息
点击此处可从《物理学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号