摘    要:微流控荧光PCR产物在高分辨率熔解(HRM)曲线分析的过程中,随着DNA的解链荧光强度发生突变,而能否检测到该突变点则依赖于温控的精度。提出了多阈值PID算法,设计了一种适用于高分辨率熔解曲线分析的FPGA温度控制系统。根据测得温度值与设定值之间的差异,改变FPGA电路系统输出的脉冲宽度调制(pulse width modulation, PWM)波占空比和算法的调节频率实现对温度的准确控制。经过温度标定后,系统温度控制精度优于0.1℃,分辨率达到±0.01℃。HRM分析实验结果表明,本方法成功地辨别出了DNA序列的单碱基差异,温度控制系统达到了设计的要求。

关 键 词:微流控  铂电阻  多阈值PID算法  脉冲宽度调制波  高分辨率熔解  
收稿时间:2014-11-11
修稿时间:2014-12-04

High Resolution Temperature Control System of Microfluidic Fluorescence PCR
FAN Shu-Guang,ZHU Ling,ZHAO Shu-Mi,Zhang Yue-Long,ZHANG Long,DENG Guo-Qing,WANG An,LIU Yong.High Resolution Temperature Control System of Microfluidic Fluorescence PCR[J].Journal of Atmospheric and Environmental Optics,2015,10(5):417-424.
Authors:FAN Shu-Guang  ZHU Ling  ZHAO Shu-Mi  Zhang Yue-Long  ZHANG Long  DENG Guo-Qing  WANG An  LIU Yong
Institution:(1 Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Institute of Applied Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China; 2.Wanjiang Center for Development of Emerging Industrial Technology, Tongling 244000, China)
Abstract:In the analysis of high resolution melting (HRM) of microfluidic fluorescence PCR amplification products, fluorescence intensity has a sudden change with the delink of DNA chain, while whether the abrupt change can be detected is dependent on the accuracy of temperature control. A kind of multi threshold PID algorithm was put forward, and a temperature control system based on FPGA was designed to adapt to the analysis of high resolution melting. Based on the difference of the measurement value and the set value, the temperature change can be controlled accurately through changing the pulse-time ratio of pulse width modulation(PWM) wave and the control frequency of the algorithm from the FPGA circuit system. After temperature calibrations of the measurement system, the accuracy precedes 0.1℃ and the resolution achieves ±0.01℃. The result of HRM experiment shows that this system can detect the single base mutation of DNA sequence successfully, and the temperature control system can meet the design requirements
Keywords:microfluidic  platinum resistance  multi threshold PID algorithm  pulse width modulation wave  high resolution melting  
本文献已被 万方数据 等数据库收录!
点击此处可从《大气与环境光学学报》浏览原始摘要信息
点击此处可从《大气与环境光学学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号