首页 | 本学科首页   官方微博 | 高级检索  
     


Simultaneous detection of dopamine and ascorbic acid in urine using the H-point standard addition method
Authors:E. Y. Hashem  Ahmed M. El-Zohry
Affiliation:(1) Department of Medicinal Chemistry, University of Mansoura, Mansoura, 35516, Egypt
Abstract:A highly sensitive H-point standard addition method (HPSAM) was investigated for identification of dopamine and ascorbic acid in some synthetic and pharmaceutical samples in an aqueous medium at pH 9.2 using a universal buffer. The most suitable wavelengths for dopamine and ascorbic acid detection are 260:271 nm and 248:270 nm respectively. Recovery values are between 99.0–101 %. Also, the effect of most common interferents was studied. Detection ranges for dopamine and ascorbic acid are 2·10–6–5·10–5 M and 6·10–6–3·10–5 M respectively with an RSD range between 1.3 and 2.0 %. The method was used to determine both reagents in real and synthesized samples.
Keywords:
本文献已被 SpringerLink 等数据库收录!