首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Headspace gas chromatographic determination of ethylene oxide in air
Authors:R Binetti  S Di Marzio  P Di Prospero  L Gramiccioni  G Viviano  G Ziemacki
Institution:(1) Laboratorio di Tossicologia Applicata, Istituto Superiore di Sanità, Viale Regina Elena 299, I-00161 Roma, Italy;(2) Laboratorio di Igiene del Territorio, Istituto Superiore di Sanità, Viale Regina Elena 299, I-00161 Roma, Italy
Abstract:Summary A simple and accurate headspace-GC method is described to determine the amount of ethylene oxide which has been collected from air using adsorption tubes containing activated charcoal and a relatively safe desorbing agent (N,N-dimethyl acetamide). The detection limit is 40μg/m3.
Keywords:Headspace gas chromatography  Ethylene oxide in air  Activated charcoal adsorption
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏