摘    要:以HNO3-H2O2为消解体系,采用微波对沉积物进行消解,建立了普里兹湾沉积物中微量元素的电感耦合等离子体质谱(ICP-MS)测定方法。从样品分析数据可以看出:8个站位10种元素总量变化范围为493.41~1481.02μg/g,总量最大值是最小值的3.00倍。元素Ba、Mn在总量中占了很大比例,V次之,而As、Mo、Ag、Cd的含量很少。大部分元素检出限可达ng/L,仅Co、Mo 2种元素的检出限稍高;各元素线性良好,相关系数r2≥0.9997。方法的RSD<5.0%,适用于普里兹湾沉积物中微量元素的定量分析。

关 键 词:普里兹湾  沉积物  微量元素  电感耦合等离子体质谱

Simultaneous determination of trace elements in sediments of prydz bay by microwave digestion-inductively coupled plasma mass spectrometry
WANG Zhi-guang,CHEN Fa-rong,ZHENG Li,ZHANG Dao-lai,Li Jun-fei,YU Xi-juan,and WANG Xiao-ru. Simultaneous determination of trace elements in sediments of prydz bay by microwave digestion-inductively coupled plasma mass spectrometry[J]. Chinese Journal of Analysis Laboratory, 2012, 0(8): 50-54
Authors:WANG Zhi-guang  CHEN Fa-rong  ZHENG Li  ZHANG Dao-lai  Li Jun-fei  YU Xi-juan  and WANG Xiao-ru
Affiliation:1.College of Chemistry and Molecular Engineering,Qingdao University of Science and Technology,Qingdao 266042;2.First Institute Oceanography of State Oceanic Administration,Qingdao 266061;3.College of Chemistry and Chemical Engineering,Ocean University of China,Qingdao 266100;4.Qingdao Institute of Marine Geology,Qingdao 266071)
Abstract:An inductively coupled plasma mass spectrometric(ICP-MS) method for the determination of trace elements in sediments of Prydz Bay was established.The samples were digested by microwave using HNO3-H2O2 as oxidants.The results showed that the total contents of ten elements in eight sites ranged from 493.41 to 1481.02 μg/g and the maximum value was 3.00 times of the minimum value.Elements Ba and Mn took a large proportion of the total sum,followed by V,while the contents of As,Mo,Ag and Cd were low.For the method,the detection limit of other elements could reach ng/L level except Co and Mo.The linear correlation cofficients of the method was preferable(r2≥0.9997).
Keywords:Prydz bay  Sediments  Trace elements  Inductively coupled plasma mass spectrometry