Characterization of the boiling width on metal quenching with spray cooling
Authors:Sabariman  Eckehard Specht
Institution:1. Electrical Engineering Department, Industrial Technology Faculty, Universitas Internasional Batam, Batam City, Indonesia;2. Institute of Fluid Dynamics and Thermodynamics, Department of Thermodynamics and Combustion, Faculty of Process and System Engineering, Otto von Guericke University, Magdeburg, Germany
Abstract:A hot aluminum alloy AA6082 and nickel disc of 560°C and 850°C was cooled by water spray of various spray flux under different condition of experiment. Temperature history was recorded with use of an infrared camera. During the quenching process, it was observed that the area with no apparent boiling and the outer annular region with vigorous liquid boiling have formed the boiling region. The width of the boiling region is essential as the maximum heat flux point is within the boiling region. Boiling width increases with initial temperature but decreases with water subcooling, spray flux and salinity.
Keywords:spray cooling  boiling width  Leidenfrost temperature  wetting front  metal quenching