首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Calorimetric measurement of the maximum glass transition temperature in a thermosetting resin
Authors:S Montserrat
Institution:1. Laboratori de Termodinàmica I Fisico-Química, Escola Tècnica Superior D'enginyers Industrials, Universitat Politècnica de Catalunya, C. Colom 11, 08222, Terrassa, Spain
Abstract:The measurement of the maximum glass transitionT g∞ of a thermosetting resin is usually performed by differential scanning calorimetry in the second scan (T g2scan), after a previous scan by heating up the sample to a temperature where the exothermic curing reaction has been completed. However, this method can eventually produce thermal degradation, decreasing the crosslinking density and theT g of the sample. Values ofT g2scan between 95? and 102?C were found in an epoxy resin based on DGEBA cured with phthalic anhydride. Thermal degradation effects can be avoided if the measurement is performed by isothermal curing and further determination ofT g. AT g∞ value of 109?C is achieved, which is the maximum value ofT g according to the topological limit of conversion.
Keywords:
本文献已被 SpringerLink 等数据库收录!