First mass spectrometric detection of boldenone in horse mane samples |
| |
Authors: | M. A. Popot N. Stojiljkovic P. Garcia Y. Bonnaire J. C. Tabet |
| |
Affiliation: | (1) LAB/FNCF, 169 Avenue de la Division Leclerc, 92290 Chatenay-Malabry, France;(2) L.C.O.B, U.M.R 7613, 4 Place Jussieu, 75252 Paris Cedex 05, France |
| |
Abstract: | Summary In order to investigate the detection of boldenone in horse mane samples, a boldenone study was conducted on two horses. The analytical procedure consisted in a hydrolysis using the Sorensen buffer, a liquid-liquid extraction using diethyl ether and a PFPA derivatization. The instrumental method was a gas chromatography sequential mass spectrometry performed on an ion trap instrument in full scan mode. The limit of detection was estimated to 1 pg mg−1. The detection of boldenone in the mane was made possible for up to 12 months after administration. |
| |
Keywords: | Gas chromatography— mass spectrometry Horse hair Boldenone |