High-performance liquid chromatographic determination of pantoprazole and its main impurities in pharmaceuticals |
| |
Authors: | Letica Jelena Marković Slavko Zirojević Jelena Nikolić Katarina Agbaba Danica |
| |
Affiliation: | Medicinal and Medical Devices Agency Serbia, Belgrade, Serbia. |
| |
Abstract: | An RP-HPLC method for simultaneous separation and quantification of pantoprazole and its five main impurities in pharmaceutical formulations was developed and validated. The separation was accomplished on a Zorbax Eclipse XDB C18 column (5 microm particle size, 150 x 4.6 mm id) using a gradient with mobile phase A [buffer-acetonitrile (70 + 30, v/v)], and mobile phase B [buffer-acetonitrile (30 + 70, v/v)]. The buffer was 0.01 M ammonium acetate solution with addition of 1 mL triethylamine/L of the solution, adjusted to pH 4.5 with orthophosphoric acid. The eluent flow rate was 1 mL/min, the temperature of the column was 30 degrees C, and the eluate was monitored at 290 nm. Linearity (r = 0.999), recovery (97.6-105.8%), RSD (0.55-1.90%), and LOQ (0.099-1.48 microg/mL) were evaluated and found to be satisfactory. The proposed method can be used for simultaneous identification and quantification of the analyzed compounds in pharmaceutical formulations. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|