Natural convection in partitioned enclosed spaces of solar collector
Authors:W. M. Chen  H. J. Shaw  M. J. Huang
Affiliation:(1) Department of Engineering Science, National Cheng-kung University, Tainan, Taiwan, 70101 Republic of China;(2) Department of Naval Architecture and Marine Engineering, National Cheng-kung University, Tainan, Taiwan, 70101 Republic of China
Abstract:The two-dimensional, steady, laminar natural convection phenomena in partitioned enclosure of solar collector has been studied numerically. Heat conduction along the partition is considered. An iterative finite-difference scheme is employed to solve the governing equations in the flow field. The effects of Rayleigh number, thermal conductivity ratio, partition angle, tilt angle, and aspect ratio on both the local and average heat transfer coefficients of the solar collector have been discussed. The range of Rayleigh number tested was up to 5 × 104, the thermal conductivity ratio of 4.5 and 30, partition angle from 10 deg to 170 deg, tilt angle from 10 deg to 90 deg, and aspect ratio varied between 0.2 and 10. The results indicate that the convective heat transfer is strongly affected with the aspect ratio of the enclosures.
Freie Konvektion in unterteilten Kammern von Solarkollektoren
Zusammenfassung Die zweidimensionale, stetige, laminare freie Konvektion in unterteilten Kammern von Solarkollektoren wurde numerisch untersucht. Die Wärmeübertragung entlang dieser Kammern wurde betrachtet. Ein iteratives Finite-Differenzen-Schema wurde angewandt um die Gleichungen, welche das Strömungsfeld beschreiben, zu lösen. Der Einfluß der Rayleigh-Zahl, der thermische Leitfähigkeit, des Kammerwinkels, des Neigungswinkels und der Längenverhältnisse auf die örtlichen und durchschnittlichen Wärmeübertragungskoeffizienten des Solarkollektors wurde diskutiert. Der Bereich der Rayleigh-Zahl erstreckte sich bis zu 5 × 104, das Verhältnis der thermischen Leitfähigkeit betrug 4.5 und 30, der Kammerwinkel lag zwischen 10° und 170°, der Neigungswinkel zwischen 10° und 90° und das Längenverhältnis variierte zwischen 0.2 und 10. Die Ergebnisse beinhalten, daß die konvektive Wärmeübertragung sehr stark durch das Längenverhältnis der Kammern beeinflußt wird.

Nomenclature a slope of the partition with respect to the horizontal - A H/L=cell aspect ratio - Aw t/L=wall aspect ratio - g acceleration due to gravity - h local heat transfer coefficient - 
$$bar h$$
average heat transfer coefficient - H cell length - k thermal conductivity of fluid within the cell - kw thermal conductivity of the cell wall - L plate spacing - Nuf h L/k=local cell Nusselt number - 
$$overline {Nu} _f$$

$$bar h$$
L/k=average cell Nusselt number - 
$$overline {Nu} _o$$
overall average Nusselt number - 
$$overline {Nu} _w$$
qL/kwt(ThTc)=average wall Nusselt number - Pr ngr/agr=Prandtl number - q heat transfer in the cell wall from the hot to cold plate per unit depth - Ra g beta L3DeltaT/ngragr=Rayleigh number - Rk kw/k=ratio of wall thermal conductivity to that of the fluid - t thickness of cell wall - Tc cold plate temperature - Tf temperature in cell - Th hot plate temperature - Tw temperature in cell wall - u, U dimension and dimensionless velocities inx-direction - v, V dimension and dimensionless velocities iny-direction - x distance measured from the bottom of the cell (Fig. 1) - X x/L=normalized distance ofx - y distance measured from hot plate (Fig. 1) - Y y/L=normalized distance ofy - x1 distance measured in wall (Fig. 1) - X1 x/L=normalized distance ofx1Greek symbols agr thermal diffusivity of fluid - beta coefficient of volumetric expansion of fluid - gamma partition angle with respect to the hot plate - thetaf TfTc/ThTc=dimensionless temperature in cell - thetaw TwTc/ThTc=dimensionless temperature in cell wall - ngr kinematic viscosity of fluid - phiv enclosure tilt angle from horizontal - ohgr dimensional vorticity - OHgr ohgrL2/agr=dimensionless vorticity - psgr dimensionless streamline
Keywords:
本文献已被 SpringerLink 等数据库收录!