Online retrieval of patient information by asynchronous communication between a general purpose computer and a stand-alone personal computer |
| |
Authors: | R Tsutsumi K Takahashi T Sato A Komatani K Yamaguchi |
| |
Affiliation: | Department of Radiology, Yamagata University School of Medicine, Japan. |
| |
Abstract: | Asynchronous communication was made between host (FACOM M-340) and personal computer (OLIBETTIE S-2250) to get patient's information required for RIA test registration. The retrieval system consists of a keyboard input of six numeric codes, patient's ID, and a real time reply containing six parameters for the patient. Their identified parameters are patient's name, sex, date of birth (include area), department, and out- or inpatient. Linking this program to RIA registration program for individual patient, then, operator can input name of RIA test requested. Our simple retrieval program made a useful data network between different types of host and stand-alone personal computers, and enabled us accurate and labor-saving registration for RIA test. |
| |