Nanogram level quantitation of oxycodone in human plasma by capillary gas chromatography using nitrogen-phosphorus selective detection. |
| |
Authors: | R P Kapil P K Padovani S Y King G N Lam |
| |
Institution: | Drug Metabolism and Pharmacokinetics Section, Stine-Haskell Research Center, Du Pont Merck Pharmaceutical Company, Newark, DE 19714. |
| |
Abstract: | A sensitive and specific capillary gas chromatographic assay is reported for the quantitation of oxycodone in human plasma. The technique involves a single extraction of oxycodone and internal standard (hydrocodone) from plasma by toluene containing 1% isopropanol. Separation is achieved on a methyl silicone (HP-1) fused-silica capillary column (25 m x 0.2 mm I.D., 0.33 microns film thickness) and detection is by nitrogen-phosphorus selective mode. The minimum quantifiable limit is 1.8 ng/ml using 2 ml of plasma. The method is applicable to characterize the plasma profile of oxycodone in humans after a single oral 5-mg oxycodone hydrochloride tablet. |
| |
Keywords: | |
|
|