Using impedance measurements to detect and quantify the effect of air leaks on the attenuation of earplugs
Authors:Henriksen Viggo
Institution:Acoustics Research Center, Department of Electronics and Telecommunications, Norwegian University of Science and Technology, NO-7491 Trondheim, Norway. viggo.henriksen@sintef.no
Abstract:The impedance of a simple artificial ear occluded with an earplug and bypassed with narrow air leaks was measured along with the attenuation of sound through the air leaks. A lumped element model is suggested for the simple occluded artificial ear with an air leak. The suggested model was adapted to the impedance measurements and the attenuation was predicted from the model. The attenuation predictions were compared to the attenuation measurements and were found to be within -3.5,+3] dB of the measured attenuation over the frequency range of 50-1000 Hz and an attenuation range of -2-38 dB. The average difference between the measured and predicted attenuation for four different leaks in the frequency range of 50-1000 Hz was -0.7 dB, indicating a very slight underestimation of the attenuation.