首页 | 本学科首页   官方微博 | 高级检索  
     

ALE FINITE ELEMENT ANALYSIS OF THE OPENING AND CLOSING PROCESS OF THE ARTIFICIAL MECHANICAL VALVE
引用本文:张建海,陈大鹏,邹盛铨. ALE FINITE ELEMENT ANALYSIS OF THE OPENING AND CLOSING PROCESS OF THE ARTIFICIAL MECHANICAL VALVE[J]. 应用数学和力学(英文版), 1996, 17(5): 403-412. DOI: 10.1007/BF00131088
作者姓名:张建海  陈大鹏  邹盛铨
作者单位:Zhang Jianhai; Chen Dapeng Zou Shengquan(Institute of Computational Engineering Science,Southwest Jiaotong University,Chengdu 610031,P,R. China) (Department of Engineering Mechanics,Sichuan Union University,Chengdu 610065,P. R. China)
摘    要:ALEFINITEELEMENTANALYSISOFTHEOPENINGANDCLOSINGPROCESSOFTHEARTIFICIALMECHANICALVALVE(张建海)(陈大鹏)(邹盛铨)ALEFINITEELEMENTANALYSISOFT...

收稿时间:1995-05-31

Ale finite element analysis of the opening and closing process of the artificial mechanical valve
Zhang Jianhai,Chen Dapeng,Zou Shengquan. Ale finite element analysis of the opening and closing process of the artificial mechanical valve[J]. Applied Mathematics and Mechanics(English Edition), 1996, 17(5): 403-412. DOI: 10.1007/BF00131088
Authors:Zhang Jianhai  Chen Dapeng  Zou Shengquan
Affiliation:(1) Institute of Computational Engineering Science, Southwest Jiaotong University, 610031 Chengdu, P. R. China;(2) Department of Engineering Mechanics, Sichuan Union University, 610065 Chengdu, P. R. China
Abstract:Employing arbitrary Lagrangian-Eulerian (ALE) finite element method, this poper studies the opening and closing process of a St. Jude medical valve through a two-dimensional model of the mechanical valve-blood interaction in which the valve is regarded as a rigid body rotating around a fixed point, and foe blood is simplified as viscous incompressible Newtonian fluid. The numerical analysis of the opening and closing behaviour of as St. Jude valve suggested that: 1. The whole opening and closing process of an artificial mechanical valve is consisted of four phases: (1) Opening phase; (2) Opening maintenance phase; (3) Closing phase; (4) Closing maintenance phase. 2. The St. Jude medical valve closes with prominent regurgitat which results in water-hammer effect. 3. During the opening and closing process of the St. Jude valve,high shear stresses occur in the middle region of the two leaflets and on the valve ring. The present model has made a breakthrough on the coupling computational analysis considering the interactive movement of the valve and blood.
Keywords:artificial mechanical valve   ALE finite element method   fluidsolid interaction
本文献已被 CNKI SpringerLink 等数据库收录!
点击此处可从《应用数学和力学(英文版)》浏览原始摘要信息
点击此处可从《应用数学和力学(英文版)》下载全文