Abstract: | In this paper, a silicon-based integrated optic pressure sensor using an intermodal interference between the fundamental TM-like and TE-like modes is described. The sensor consists of a micromachined rectangular diaphragm and a straight polystyrene optical waveguide passing over the diaphragm. Its sensitivity is theoretically known to be strongly dependent on the position of the waveguide over the diaphragm. To experimentally investigate such dependence, we fabricated a sensor with a 1.2 mm ×10 mm ×20 μm diaphragm, over which waveguides were placed at 50 μm intervals. The measured phase sensitivity was 98 mrad/kPa for the waveguide nearest to the diaphragm edge. The measurement was also carried out for the other waveguides. As theoretically expected, the largest sensitivity was obtained for the waveguide nearest to the edge. |