A novel sealing method in static coating fused-silica capillary column
Authors:H F Yin  A J Huang  Y L Sun
Institution:(1) Department of Chemistry, Beijing University, 100871 Beijing, People's Republic of China
Abstract:Summary In this paper a new sealing method for the static coating of capillary columns is described. When one end of the fully filled capillary was immersed into liquid nitrogen in a Dewar flask, the coating solution at this end would be frozen and became a temporary seal, and an air-free solvent/seal interface was obtained. No bumping has ever been found at the interface, even when butane was used as solvent. By applying this sealing method, several capillary columns, including some narrow bore capillary, had been successfully coated.
Keywords:Gas chromatography  Fused-silica columns  Static coating  Sealing method
本文献已被 SpringerLink 等数据库收录!