首页 | 本学科首页   官方微博 | 高级检索  
     

250 keV He+ 离子注入钽酸锂改性研究
引用本文:庞立龙,王志光,姚存峰,崔明焕,孙建荣,申铁龙,魏孔芳,朱亚滨,盛彦斌,李远飞,李锦钰. 250 keV He+ 离子注入钽酸锂改性研究[J]. 原子核物理评论, 2013, 30(1): 67-71. DOI: 10.11804/NuclPhysRev.30.01.067
作者姓名:庞立龙  王志光  姚存峰  崔明焕  孙建荣  申铁龙  魏孔芳  朱亚滨  盛彦斌  李远飞  李锦钰
作者单位:中国科学院近代物理研究所,甘肃兰州730000;
基金项目:国家自然科学基金资助项目(10835010);国家重大基础研究发展计划项目(973计划)(2010CB832902)~~
摘    要:室温下,将能量为250 keV He+ 离子注入z 切钽酸锂单晶,注量范围5.0x1014~5.0x1016 He+/cm2,应用三维轮廓仪、X射线衍射(XRD)、紫外可见(UV-Vis ) 光学吸收谱对未注入和注入样品进行了表征和分析。分析结果表明,在注量达到5.0x1016He+/cm2 时,样品表面出现大量凸起条纹,同时晶格沿着[001] 方向出现明显肿胀,吸收边则表现出明显的注量相关性。注入样品在空气中放置60 d后,最高注量的样品表面原来凸起的条纹变为细长的裂纹,晶格应变及光学吸收边均出现较大的恢复。讨论了样品表面形貌、晶格应变和光学吸收边与He 行为的关系。The effects of 250 keV He + implantation in the fluence from 5.0x1014 to 5.0x1016 He+/cm2 on lithium tantalate at room temperature were investigated by 3D surface profiler, XRD and UV-Vis optical absorption spectroscopies.The experimental results show that a large number of raised stripes appear on the surface of the sample and the significant lattice swelling occurs along the direction [ 001 ] at the fluence of 5.0x1016 He+/cm2. The dependence of changes absorption edge on the fluences was revealed. After the samples had been exposed to the air for 60 days, the raised stripes on the surface have evolved into narrow cracks. Furthermore, the lattice strain and the optical absorption edge has also recovered dramatically. The relationship between surface morphology, lattice strain, optical absorption edge and behaviorof He-ions was discussed.

关 键 词:钽酸锂   He+ 注入   表面形貌   X射线衍射   光学吸收边
收稿时间:1900-01-01

Modification of Lithium Tantalate Implanted by 250 keV He-ions
PANG Li-long,WANG Zhi-guang,YAO Cun-feng,CUI Ming-huan,SUN Jian-rong,SHEN Tie-long,WEI Kong-fang,ZHU Ya-bin,SHENG Yan-bin,LI Yuan-fei,LI Jin-yu. Modification of Lithium Tantalate Implanted by 250 keV He-ions[J]. Nuclear Physics Review, 2013, 30(1): 67-71. DOI: 10.11804/NuclPhysRev.30.01.067
Authors:PANG Li-long  WANG Zhi-guang  YAO Cun-feng  CUI Ming-huan  SUN Jian-rong  SHEN Tie-long  WEI Kong-fang  ZHU Ya-bin  SHENG Yan-bin  LI Yuan-fei  LI Jin-yu
Affiliation:Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China;
Abstract:The effects of 250 keV He + implantation in the fluence from 5.0x1014 to 5.0x1016 He+/cm2 on lithium tantalate at room temperature were investigated by 3D surface profiler, XRD and UV-Vis optical absorption spectroscopies.The experimental results show that a large number of raised stripes appear on the surface of the sample and the significant lattice swelling occurs along the direction [ 001 ] at the fluence of 5.0x1016 He+/cm2. The dependence of changes absorption edge on the fluences was revealed. After the samples had been exposed to the air for 60 days, the raised stripes on the surface have evolved into narrow cracks. Furthermore, the lattice strain and the optical absorption edge has also recovered dramatically. The relationship between surface morphology, lattice strain, optical absorption edge and behaviorof He-ions was discussed.
Keywords:Lithium tantalate  He-ions implantation  surface morphology  XRD  optical absorption edge
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《原子核物理评论》浏览原始摘要信息
点击此处可从《原子核物理评论》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号