Effect of the nonlinearity of the CCD in Fourier transform profilometry on spectrum overlapping and measurement accuracy |
| |
Authors: | Qiao Nao-Sheng ab and Zou Bei-Ji |
| |
Affiliation: | Qiao Nao-Sheng a)b) and Zou Bei-Ji a) School of Information Science and Engineering, Central South University, Changsha 410083, China b) School of Physics and Electronics, Hunan University of Arts and Science, Changde 415000, China |
| |
Abstract: | ![]() In Fourier transform profilometry (FTP), we must restrain spectrum overlapping caused by the nonlinearity of the charge coupled device (CCD) and increase the measurement accuracy of the object shape. Firstly, the causes of producing higher-order spectrum components and inducing spectrum overlapping are analysed theoretically, and a simple physical explanation and analytical deduction are given. Secondly, aiming to suppress spectrum overlapping and improve measurement accuracy, the influence of spatial carrier frequency of projection grating on them is analysed. A method of increasing the spatial carrier frequency of projection grating to restrain or reduce the spectrum overlapping significantly is proposed. We then analyze the mechanism of how the spectrum overlapping is reduced. Finally, the simulation results and experimental measurements verify the correction of the proposed theory and method. |
| |
Keywords: | spectra overlapping measurement accuracy nonlinearity of CCD Fourier transform profilometry |
本文献已被 CNKI 维普 等数据库收录! |
|