首页 | 本学科首页   官方微博 | 高级检索  
     检索      

封闭溶样-电感耦合等离子体质谱法测定地质样品中痕量金
引用本文:张勇,王玉功,刘建军.封闭溶样-电感耦合等离子体质谱法测定地质样品中痕量金[J].中国无机分析化学,2013,3(1):34-37.
作者姓名:张勇  王玉功  刘建军
作者单位:陕西省地质矿产勘查开发局第六地质队,国土资源部兰州矿产资源监督检测中心 甘肃 兰州
摘    要:建立了聚乙烯塑料瓶封闭水浴加热,王水溶解,以铼作内标,电感耦合等离子体质谱法测定地质样品中痕量金。结果表明,样品中的金可分解完全,节约了成本、减少了环境污染。方法经国家一级标准物质验证,结果与标准值相符。对实际样品测定的方法相对标准偏差(RSD,n=9)为4.1%~6.7%。方法检出限为0.12ng/g,方法简便快速,适用于地质样品的批量分析。

关 键 词:封闭溶样  水浴  泡塑吸附  电感耦合等离子体质谱法  
收稿时间:2012/9/14 0:00:00
修稿时间:2012/11/28 0:00:00

Determination of Trace Gold in Geological Samples by Inductively Coupled Plasma Atomic Emission Spectrometry with Pressurized Sample Decomposition Technique
ZHANG Yong,WANG Yugong and LIU Jianjun.Determination of Trace Gold in Geological Samples by Inductively Coupled Plasma Atomic Emission Spectrometry with Pressurized Sample Decomposition Technique[J].Chinese Journal of Inorganic Analytical Chemistry,2013,3(1):34-37.
Authors:ZHANG Yong  WANG Yugong and LIU Jianjun
Institution:ShanXi Sixth Geological Team for Geological and Mineral Exploration,The Development Bureau,Xi'an,ShanXi 710611,China;Lanzhou Testing and Quality Supervision Center for Geological and Mineral Products,The Ministry of Land and Resources,Lanzhou Gansu 730050,China;Lanzhou Testing and Quality Supervision Center for Geological and Mineral Products,The Ministry of Land and Resources,Lanzhou Gansu 730050,China
Abstract:A new inductively coupled plasma mass spectrometry(ICP-MS) method was established for the determination of trace gold in geological samples. The novelty of this method is the utilization of a polyethylene plastic bottle to seal the heating bath. The samples were digested with aqua regia solution and analysis was conducted using rhenium internal standard. The experimental results indicates that due to sealing of the water bath with polyethylene plastics bottles, the gold of the ore samples can be completely decom posed, which result in saving cost and reducing environmental contamination. The method has been verified by analysis of national primary reference materials and results are consistent with the standard values. The relative standard deviation for the method was 4.1%~6.7% (RSD, n=9). The detection limit was 0.12 ng/g. It concludes that the method is suitable for analysis of bulk field sample.
Keywords:Pressurized Decomposition  Water bath  Foam plastic adsorption  Inductively Coupled Plasma Atomic Emission Spectrometry  gold  
本文献已被 CNKI 维普 等数据库收录!
点击此处可从《中国无机分析化学》浏览原始摘要信息
点击此处可从《中国无机分析化学》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏