首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Influence of temperature and humidity on NO x removal by corona discharge
Authors:Miroslaw Dors  Jerzy Mizeraczyk
Institution:(1) Institute of Fluid Flow Machinery, Polish Acad. Sci., Fiszera 14, 80-952 Gdańsk, Poland
Abstract:The object of this experimental investigation was the influence of temperature and humidity on the efficiency of removal of NO x by a pulsed corona discharge from a mixture N2 : O2 : CO2 : H2O : NO simulating a combustion flue gas. The pulsed corona discharge was generated in a wire-to-cylinder reactor. It was found that removal of NO x was most efficient when H2O concentration corresponded with the saturated vapour pressure. In the case of the operating gas containing constant H2O concentration removal of NO x decreased with increasing temperature of the operating gas. Dedicated to Prof. Jan Janča on the occasion of his 60th birthday. This work is devoted to the 60th birthday of Professor Jan Janca, our good colleague, merited teacher, researcher and famous physicist, discussion with whom stimulated this and other our work during years.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏