首页 | 本学科首页   官方微博 | 高级检索  
     检索      

能量连续可调LCS光源SINAP-III
引用本文:徐望,罗文,黄勃松,安振东,李永江,杨利峰,范功涛,阎喆,徐本基,蔡晓鹭,潘强岩,樊广伟.能量连续可调LCS光源SINAP-III[J].原子核物理评论,2012,29(3):253-258.
作者姓名:徐望  罗文  黄勃松  安振东  李永江  杨利峰  范功涛  阎喆  徐本基  蔡晓鹭  潘强岩  樊广伟
作者单位:中国科学院上海应用物理研究所, 上海 201800
基金项目:国家自然科学基金重点项目
摘    要:X/γ探测器在航天等国家战略需求领域具有非常广泛和重要的应用。 然而, X/γ探测器要在其有效能区进行精确的标定后才能发挥作用。 目前我国缺乏sub MeV~MeV能量连续可调、 单色性好的γ源, 而用于航天的X/γ探测器无法完成精确定标, 从而使航天探测的发展出现瓶颈问题。 提出了升级原有的激光康普顿散射(LCS)原理性实验装置的方案, 建立了一个通过改变激光入射角来连续调节散射光子能量、 准单色、 极化、 sub MeV~MeV LCS光源(SINAP-III), 从而开拓LCS光源在我国航天领域(如用于航天的X/γ探测器能量定标和抗辐射加固评估研究)的崭新应用前景, 并为将来建设一个基础和应用研究相结合的多功能的γ源实验平台打下基础。 The X/γ detectors in the field of national stratagem, such as astronautical technology, have very broad and important application. These detectors, however, will play their role properly only after accurate calibrations in effective energy region. For the shortage of continuously adjustable and quasi monochromatic γ source in China, it is impossible for the detector employed in aerospace to achieve an accurate calibration so that development of such detector has encountered a big obstacle (or a bottleneck). Therefore, we propose to upgrade the original LCS device to an adjustable photon energy by changing incident angle of laser beam, monochromatic, and polarized sub MeV~MeV LCS γ source(SIMAP III) , in order to explore the new applications of LCS γ source in aerospace as well as to establish a platform for a multifunctional of γ source.

关 键 词:LCS光源    能量可调    航天用探测器定标    可旋转靶室
收稿时间:1900-01-01

Adjustable LCS y Source SINAP-III
XU Wang,LUO Wen,HUANG Bo-song,AN Zhen-dong,LI Yong-jiang,YANG Li-feng,FAN Gong-tao,YAN Zhe,XU Ben-ji,CAI Xiao-lu,PAN Qiang-yan,FAN Guang-wei.Adjustable LCS y Source SINAP-III[J].Nuclear Physics Review,2012,29(3):253-258.
Authors:XU Wang  LUO Wen  HUANG Bo-song  AN Zhen-dong  LI Yong-jiang  YANG Li-feng  FAN Gong-tao  YAN Zhe  XU Ben-ji  CAI Xiao-lu  PAN Qiang-yan  FAN Guang-wei
Institution:Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China
Abstract:The X/γ detectors in the field of national stratagem, such as astronautical technology, have very broad and important application. These detectors, however, will play their role properly only after accurate calibrations in effective energy region. For the shortage of continuously adjustable and quasi monochromatic γ source in China, it is impossible for the detector employed in aerospace to achieve an accurate calibration so that development of such detector has encountered a big obstacle (or a bottleneck). Therefore, we propose to upgrade the original LCS device to an adjustable photon energy by changing incident angle of laser beam, monochromatic, and polarized sub MeV~MeV LCS γ source(SIMAP III) , in order to explore the new applications of LCS γ source in aerospace as well as to establish a platform for a multifunctional of γ source.
Keywords:LCS y source adjustable energy detector calibration for aerospace rotatable target chamber
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《原子核物理评论》浏览原始摘要信息
点击此处可从《原子核物理评论》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号