Fluorescence saturation measurements of 3-pentanone |
| |
Authors: | B. R. Petersen J. B. Ghandhi J. D. Koch |
| |
Affiliation: | 1. Engine Research Center, University of Wisconsin-Madison, 1500 W. Engineering Dr., Madison, WI, 53706, USA 2. Department of Mechanical Engineering, Marquette University, 1515 W. Wisconsin Ave., Milwaukee, WI, 53233, USA
|
| |
Abstract: | The saturation characteristics of 3-pentanone fluorescence were investigated in an ambient temperature and pressure cell by imaging the fluorescence produced by a focused quadrupled Nd:YAG laser beam. The onset of fluorescence saturation was observed at laser fluences around 0.06 J/cm2, which is only about 1.3% of estimates that assume a two-level model and use measured values of the fluorescence lifetime and absorption cross-section. A spatially resolved model indicated that the saturation fluence changed only 10% when a Gaussian profile was used instead of a top-hat profile. Laser sources with significantly different temporal profiles will have different threshold fluence levels, but the present results suggest that saturation effects should be monitored in planar laser-induced fluorescence imaging experiments using 3-pentanone. |
| |
Keywords: | |