首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Electric field simulation and measurement of a pulse line ion accelerator
Authors:SHEN Xiao-Kang  ;  ZHANG Zi-Min  ;  CAO Shu-Chun  ZHAO Hong-Wei  WANG Bo  SHEN Xiao-Li  ZHAO Quan-Tang  ;  LIU Ming  JING Yi
Institution:1 Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China 2 Graduate University of Chinese Academy of Sciences, Beijing 100049, China 3 Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
Abstract:An oil dielectric helical pulse line to demonstrate the principles of a Pulse Line Ion Accelerator (PLIA) has been designed and fabricated. The simulation of the axial electric field of an accelerator with CST code has been completed and the simulation results show complete agreement with the theoretical calculations. To fully understand the real value of the electric field excited from the helical line in PLIA, an optical electric integrated electric field measurement system was adopted. The measurement result shows that the real magnitude of axial electric field is smaller than that calculated, probably due to the actual pitch of the resister column which is much less than that of helix.
Keywords:PLIA  accelerator  electric field measurement  sensor
本文献已被 CNKI 等数据库收录!
点击此处可从《中国物理 C》浏览原始摘要信息
点击此处可从《中国物理 C》下载免费的PDF全文