Electron microprobe analysis of micro amount powder samples: A case study on high purity coal |
| |
Authors: | Kaspar Honegger Wilfried Wintsch |
| |
Affiliation: | (1) Gebr. Sulzer AG, Forschung und Entwicklung, KSFE Werkstoffkunde 1511, CH-8400 Winterthur, Schweiz |
| |
Abstract: | For the major, minor and trace element analysis of the inorganic compounds of a Ruhr-Saar coal different preparation techniques are investigated with X-ray fluorescence analysis, electron microprobe and classical wet chemical methods minimizing sample weight at standard preparation times and analytical accuracies. Considering accuracy as well as preparation efforts, determinations by electron microprobe on small sample amounts (<50 mg) proved to be superior to the other methods.Abbreviations AAS atomic absorbtion spectrometry - EMA electron microprobe analysis - IC ion chromatography - ISE ion sensitive electrode - PHOT photometry - WCA wet chemical analysis - XRF X-ray fluorescence analysis - LTA low temperature plasma ashing - HTA high temperature ashing - l.o.i. loss on ignition |
| |
Keywords: | powder samples high purity coal coal analysis sampling techniques electron microprobe analysis |
本文献已被 SpringerLink 等数据库收录! |