首页 | 本学科首页   官方微博 | 高级检索  
     


Hybrid multi-resolution detection of moving targets in infrared imagery
Affiliation:1. Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, PR China;2. Wards 40 of Cardiology Department, Beijing Anzhen Hospital, Capital Medical University, Beijing, PR China;3. Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University or South Carolina, Charleston, SC, USA;4. Division of Cardiology, Department of Internal Medicine, Medical University or South Carolina, Charleston, SC, USA;5. Center for Medical Imaging North-East Netherlands (CMI-NEN), University of Groningen, University Medical Center Groningen, Groningen, The Netherlands;6. Department of Medical Radiation Sciences, Curtin University, Perth, WA 6845, Australia
Abstract:A hybrid moving target detection approach in multi-resolution framework for thermal infrared imagery is presented. Background subtraction and optical flow methods are widely used to detect moving targets. However, each method has some pros and cons which limits the performance. Conventional background subtraction is affected by dynamic noise and partial extraction of targets. Fast independent component analysis based background subtraction is efficient for target detection in infrared image sequences; however the noise increases for small targets. Well known motion detection method is optical flow. Still the method produces partial detection for low textured images and also computationally expensive due to gradient calculation for each pixel location. The synergistic approach of conventional background subtraction, fast independent component analysis and optical flow methods at different resolutions provide promising detection of targets with reduced time complexity. The dynamic background noise is compensated by the background update. The methodology is validated with benchmark infrared image datasets as well as experimentally generated infrared image sequences of moving targets in the field under various conditions of varying illumination, ambience temperature and the distance of the target from the sensor location. The significant value of F-measure validates the efficiency of the proposed methodology with high confidence of detection and low false alarms.
Keywords:Moving target detection  Thermal infrared imagery  Background subtraction  FastICA  Optical flow
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号