首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Oxygen stripping in deaerator feed water: condensation on spray droplets
Authors:K V Sharma  K V Suryanarayana  P K Sarma  V Dharma Rao  T Subramanyam
Institution:(1) Faculty of Mechanical Engineering, Universiti Malaysia Pahang, 26600 Pekan, Pahang, Malaysia;(2) Department of Chemical Engineering, Sri Venkateswara Engineering College, Suryapet, 508213, India;(3) International Director, GITAM University, Visakhapatnam, 530045, India;(4) Department of Chemical Engineering, A.U College of Engineering, Visakhapatnam, 530003, India;(5) Department of Mechanical Engineering, A.U College of Engineering, Visakhapatnam, 530003, India
Abstract:Deaerator is used to remove oxygen from boiler feed-water. Experiments with deaerator indicate that the droplet diameter decreases with increasing the mass flow rate of water and the increasing deaerator pressure leads to increase in heat and mass transfer coefficients. The mass transfer coefficients are found to increase with increasing the deaerator pressure, the independent of length and the oxygen concentration in inlet water.
Keywords:
本文献已被 SpringerLink 等数据库收录!