首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Abnormal Fluorescence Behavior of Pyrene Functionalized Chitosan Films to Some Quenchers
作者姓名:王晓妮  张洁
摘    要:Investigation of the fluorescence behavior of a pyrene functionalized chitosan film (PSC-CS) to some quenchers,including KI,CH3NO2 and Cu(NO3)2,has revealed that the monomer emission from the PSC-CS film increased rather than decreased,whereas the excimer emission decreased with the increase of time of duration after addition of KI or Cu(NO3)2.Both the increasing and decreasing processes could last as long as 20min to 40min,Unlike that observed in the system containing KI or Cu(NO3)2,for CH3NO2 system,both the monomer emission and the excimer emission increased with introduction of the quencher,but the excimer emission only started to increase after an hour-long induction period.The position of the excimer emission of the PSC-CS film did not change very much with addition of KI or Cu(NO3)2.However,addition of CH3NO2 made the excimer emission blue shifted for at least 20nm indicating formation of distorted excimers opr partially overlapped excimers.The fluorescence response of the film to external additions is sensitive but is low in selectivity.This property may make the film use as a novel sensing material for monitoring the purity of water.

关 键 词:脱乙酰壳聚糖薄膜  功能化修饰    功能薄膜  荧光性质  纯水

Abnormal Fluorescence Behavior of Pyrene Functionalized Chitosan Films to Some Quenchers
Zhang Shu‐Juan,Fang Yu,Hu Dao‐Dao,Gao Gai‐Ling.Abnormal Fluorescence Behavior of Pyrene Functionalized Chitosan Films to Some Quenchers[J].Chinese Journal of Chemistry,2003,21(3):249-252.
Authors:Zhang Shu‐Juan  Fang Yu  Hu Dao‐Dao  Gao Gai‐Ling
Abstract:Investigation of the fluorescence behavior of a pyrene functionalized chitosan film (PSC‐CS) to some quenchers, including KI, CH3NO2 and Cu(NO3)2, has revealed that the monomer emission from the PSC‐CS film increased rather than decreased, whereas the excimer emission decreased with the increase of time of duration after addition of KI or Cu(NO3)2. Both the increasing and decreasing processes could last as long as 20 min to 40 min. Unlike that observed in the system containing KI or Cu(NO3)2, for CH3NQ2 system, both the monomer emission and the excimer emission increased with introduction of the quencher, but the excimer emission only started to increase after an hour‐long induction period. The position of the excimer emission of the PSC‐CS film did not change very much with addition of KI or Cu(NO3)2. However, addition of CH3NO2 made the excimer emission blue shifted for at least 20 nm indicating formation of distorted excimers or partially overlapped excimers. The fluorescence response of the film to external additions is sensitive but is low in selectivity. This property may make the film use as a novel sensing material for monitoring the purity of water.
Keywords:chitosan  pyrene  fluorescence quenching  water purity
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号